WL15ASpectrometer

Introduction
WL15A provides fast, stable, and precise analysis to realize perfect sample detection requirements. It is a powerful and most reliable spectrometer with optical system using CCD detector, small size and highly cost-effective.

Optical System
- Pa-type Runge optical structure, Roland circular grating beam-splitting chambe
- Grating: Score 2700 lines / mm, focal length: 400mm
- Wavelength range: 140-700mm
- Light chamber: constant temperature integrated light chamber, automatic constant temperature 35 ℃, accuracy ± 0.1 ℃.
Analysis Mode
The sample be quickly identified by pre-installed metal grades. You can freely choose the analysis mode, configure the analysis curve, and optimize the parameters according to the application requirements.
Vacuum System
- Vacuum degree: vacuum control is less than 2pa.
- Vacuum timing control, integral vacuum body patent, short working time.
- Vacuum pump; with anti-oil device to ensure that the light chamber is not polluted by oil.
- Intermittent vacuum control device: pump air for 3-5 mins, and can keep for > 5 hours.
Spark Excitation System
WL15A adopts full-frequency digital double-pulse excitation light source, variable frequency(200-800Hz) excitation technology, and double spark combined discharge to ensure the stability of the light source in the spark excitation system.
CCD Detector
Japanese Hamamatsu, research-level CCD, high sensitivity, wide linear range, good reproducibility, good stability and fast response.1 6-channel, high-precision CCD (CMOS optional), 3648px,total pixels > 50,000, high-resolution full-spectrum acquisition.
Excitation Platform

Excitation Light Source
Digital double pulse excitation light source, excitation frequency 200-800Hz;Dual-channel excitation device; the sample excitation adopts dual-channel and the data stability is higher; There are no resistive parts in the excitation circuit, no heat is generated during detection, and thermal stability is improved.
Open excitation platform
adaptable to larger sample analysis. The sample excitation adopts horizontal and vertical dual-gas path to make provoking more stable. Intelligent air pressure protection device for the excitation of argon gas make provoking safer.
Easy to use
Operating interface in Chinese under Windows system, with multiple language modes. One-click activation to obtain data. Built-in self-diagnosis system.
Analysis Software: simple operation, fast analysis, system stability
- Chinese interface analysis software under Windows System, switchable multiple-language version to automat, cally complete setting analysis parameters, excitation, flushing, selecting pre-combustion ignition time.
- Analysis curve, control sample correction, choose two-point or single-point standardization and calibration.
- One or more excitations can be repeated at the same point, and abnormal results can be deleted
- Automatically calculate the average value, SD and RSD, and export Word and Excel documents.
- Built-in fault diagnosis and self-test program, which can remotely judge the fault of the instrument.

Diverse small sample fixtures
A combination of flexible and accurately positioned fixtures, suitable for various shapes and specifications of wire and rod materials.
High Analysis Accuracy and Fast
Automatically detect samples and complete elemental analysis of samples in 10-30s.
SPECIFICATIONS
ITEM
Light System
Excitation
Platform
Detector
Vacuum Ultraviolet System
Optical System
Read-out
System
Computer
Power
Environment Requirements
Spectral Environment
Size and Weight
TYPE: WL15A
A dual pulse digital frequency light source, variable frequency (200 – 800Hz) excitation technology
Wear-resistant, corrosion-resistant chromium-based stainless steel with an intelligent pressure protection device
Hamamatsu / Toshiba
multiple high-precision CCDs (CMOS optional) 3648px
total pixels> 50,000, High-resolution full-spectrum acquisition
Intermittent work, working pressure 0.1-5Pa
working time>5 hours, optional molecular sieve, isolation valve
Pa-type, Rorand grating
focal length 400mm, 2700g/mm, wavelength range 140-700nm;
High-speed 16bit ADC digital conversion, FPGA digital signal controller with an industrial USB data acquisition (100 KHz/s)
and high-speed multi-channel synchronous digital collection (1.6 million times/second)
The external brand computer, Windows operating system, display, and printer
External power parameters of 220V+10%, 50Hz.
Maximum power of 200-1000VA: 10A slow-blow fuse
Relative humidity 20%-80%, working temperature 10-35° C
No corrosive gases or high dust pollution
810x660x380mm, 80kg